The Valcourt VA4460 forced air kit moves heat from a Waterloo, Dallaire II or St-Louis wood fireplace to another room through 6 inch insulated duct. A 120 V blower, mounted at least 10 ft from the fireplace, moves the warm air up to 50 ft away. A rheostat sets the speed, and a thermal switch can start and stop the fan with the fire.

6" insulated ductUL 181 / ULC S110 flex
120 V blowerWith rheostat speed control
Up to 50 ftFrom the fireplace
3 Valcourt modelsWaterloo, Dallaire II, St-Louis

Details

Part numberVA4460
FitsValcourt Waterloo FP15 and FP15A, Dallaire II FP18R, St-Louis FP19
Main partsBlower, rheostat, 6" fan adapter, duct collars, fireplace connector, air outlet
Power120 V
Thermal switchStarts the fan at 110°F (50°C), stops it below 90°F (32°C)
Duct6" insulated flexible duct listed to UL 181 and ULC S110, at least 25 ft total
ReachUp to 50 ft from the fireplace
Blower locationAt least 10 ft from the fireplace, outside its enclosure, 2" from combustibles
BrandValcourt (SBI)
Wiring by a certified electrician.The kit manual says the wiring should be done by a certified electrician and strongly recommends professional installation. Turn the fan off before opening the fireplace doors.

Questions people ask us

Which fireplaces does the VA4460 fit?

Valcourt lists it for the Waterloo FP15 and FP15A, the Dallaire II FP18R and the St-Louis FP19.

Is the flex duct included?

Plan on the 6" x 25' insulated flex pipe AC01350, which Valcourt lists as a separate option for its forced air kits. The kit manual calls for at least 25 ft of 6" insulated duct.

Can I tie it into my furnace ducts?

The manual says not to connect any hot air duct to a cold air return. If it is connected to a furnace hot air system, a backflow shutter is needed between the fan and the furnace duct, and in Canada a furnace connection is not allowed unless local codes permit it.

Where does the blower go?

At least 10 ft from the fireplace, outside its enclosure, with 2" to combustibles and access for maintenance.

Not sure the kit suits your layout?

Send us the fireplace model and where you want the heat, and we will check the run with you.

Goes with this

Manuals and warranty

Valcourt manuals and warranty

Warranty terms come from Valcourt and depend on the product. Read the manual and the warranty for your model before you order.

Our warranty library· Forced air kit VA4460 manual (PDF)
Not sure this is the right kit? Send us the fireplace model and a sketch of the duct run, and we will confirm the kit and pipe before you order. No obligation either way.
Ask us before you order