The Athena Drop-In Linear Pan is a 6 inch wide 304 stainless steel burner pan with a matching T-burner fitted, made in 36, 48, 60 and 72 inch lengths. It drops into a linear fire table or trough and ships with both a natural gas and a propane orifice. The raised bottom cuts down the glass and filler you need. Part numbers DIP-LN-36, DIP-LN-48, DIP-LN-60 and DIP-LN-72.
Details
| DIP-LN-36 | 36" x 6" pan (38 1/2" x 8 1/2" in the manual chart), 36" T-burner, 65,000 BTU NG or LP |
|---|---|
| DIP-LN-48 | 48" x 6" pan (50 1/2" x 8 1/2" in the manual chart), 48" T-burner |
| DIP-LN-60 | 60" x 6" pan (62 1/2" x 8 1/2" in the manual chart), 60" T-burner |
| DIP-LN-72 | 72" x 6" pan (74 1/2" x 8 1/2" in the manual chart), 72" T-burner |
| Material | 16-gauge 304 stainless steel pan with a raised bottom |
| Included | Pan with burner, natural gas orifice, propane orifice, flex line and fittings, installation manual |
| Gas connection | 1/2" FIP x 5/8" flare fitting at the pan, 5/8" flex line |
| Gas pressure, NG | 3.5" to 14" W.C., 7" W.C. normal |
| Gas pressure, LP | 8" to 14" W.C., 11" W.C. normal |
| Clearance to combustibles | 36" to the sides, 96" above |
| Ventilation | 18 sq. in. of cross ventilation in every installation |
| Brand | Athena |
Questions people ask us
Which length fits my fire table?
The pan comes in 36, 48, 60 and 72 inch lengths, all 6 inches wide, and the installation manual lists the pan at 2 1/2 inches longer and wider than its nominal size. Send us your opening and we will check the fit.
What comes in the box?
The burner and pan, a natural gas orifice, a propane orifice, the flex line and fittings, and the installation manual. The manual connects the incoming gas line through a key valve, which is not in the parts list, so plan for a valve or control.
What media can I use?
The manual calls for 1/2 to 3/4 inch fire glass rated for fire use, with no more than 1 inch of media over the top of the burner, or 1 to 2 inch lava rock placed loosely. Keep the weep holes in the pan clear. Browse Athena fire glass.
What does the installation need?
Outdoor use only, never on grass, dirt or soft material. The manual requires 18 sq. in. of cross ventilation, 36 inches of clearance to combustibles at the sides and 96 inches above. A licensed gas professional should make the gas connection to the instructions and local codes.
Can I buy the T-burner on its own?
Yes. The Athena T-Burner is sold separately in the same four lengths.