Osburn
Osburn 2000 Wood Insert
Osburn 2000 Wood Insert


The Osburn 2000 insert (OB02016) is a non-catalytic wood insert for an existing masonry fireplace, rated for 500 to 2,100 sq ft with a maximum heat output of 75,000 BTU/h. It brings the 2.4 cu ft firebox of the Osburn 2000 stove into a fireplace opening. The firebox takes logs up to 20" long and burns up to 8 hours, and a 144 CFM blower is included. Faceplates, sold separately, cover a masonry hearth up to 32" high and 50" wide.
Specifications
| Model | Osburn 2000 wood insert, OB02016 |
|---|---|
| Heat output | 75,000 BTU/h maximum (dry cordwood); overall 14,200 to 44,500 BTU/h |
| Heating area | 500 to 2,100 sq ft |
| Efficiency | 72% average overall (HHV), 77% (LHV); 79% optimum overall |
| Emissions | 2.3 g/h average particulate, non-catalytic |
| Test standard | EPA 2020 approved; tested to ASTM E3053-17 under 40 CFR Part 60, Subpart AAA; efficiency by the CSA B415.1-10 stack loss method |
| Firebox | 2.4 cu ft overall (1.95 cu ft EPA loading volume); 11 7/8" H x 21" W x 16 3/4" D |
| Burn time and logs | Up to 8 hours; logs up to 20" long, loaded across the width |
| Overall size | 23 1/8" H x 28 3/8" W x 26 3/8" D |
| Minimum fireplace opening | 23 3/8" H x 28 7/8" W x 15 3/4" D |
| Flue | 6" outlet; continuous 6" liner to the top of the chimney (UL 1777), 12 ft minimum chimney height |
| Clearances (US) | Side mantle 9", top mantle 27", side wall 16", 84" to the top from the platform; floor protection 16" in front |
| Shipping weight | 434 lb |
| Brand | Osburn (SBI) |
Questions people ask us
What do I need to order with the 2000 insert?
Osburn lists three required accessories, sold separately: a door overlay (black or brushed nickel), a faceplate (Regular 29" x 44" or Large 32" x 50") and matching faceplate trims. A faceplate extension is included with the insert for most hearths. See the trims and fronts collection.
Is the blower included?
Yes. A 144 CFM variable speed blower comes with the insert.
Can the 2000 insert go in a factory-built fireplace?
No. Osburn states that its wood-burning inserts must only be installed inside an existing masonry fireplace with a lined masonry chimney, never in a factory-built (zero clearance) fireplace or any wooden or combustible structure.
What chimney liner does it need?
A continuous 6" liner from the insert to the top of the chimney, listed to UL 1777 in the US, with a minimum chimney height of 12 ft. Liner adapters are in the venting collection.
Will it fit my fireplace?
The minimum opening is 23 3/8" H x 28 7/8" W x 15 3/4" D. Send us your measurements and we will check it with you. Ask us here.
Goes with this
Manuals and warranty
Warranty terms come from Osburn and depend on the product. Read the manual and the warranty for your model before you order.
Our warranty libraryยท Osburn 2000 wood insert install and owner's manual (PDF)ยท Osburn 2000-I dimensions (PDF)Ask us before you order