Astria
Astria Gemini DLX Natural Gas to Propane Conversion Kit
Astria Gemini DLX Natural Gas to Propane Conversion Kit


The Astria GCKGDLX35NP and GCKGDLX40NP are natural gas to propane conversion kits for the Gemini DLX 35 and Gemini DLX 40 direct vent gas fireplaces with the EcoFlow electronic valve. Each kit has the propane main burner orifice and low-rate orifice for its size, plus the conversion sticker and form. Catalog numbers F3673 (35) and F3675 (40). A qualified service agency must install it.
Details
| GCKGDLX35NP | Catalog F3673, for the GeminiDLX35 |
|---|---|
| GCKGDLX40NP | Catalog F3675, for the GeminiDLX40 |
| Conversion | Natural gas to propane |
| Valve | EcoFlow electronic ignition |
| Contents | Main burner orifice, low-rate orifice, conversion sticker, conversion sticker form |
| Propane orifices, 35 | Main burner #54 (0.055"), low-rate #50 (0.070") |
| Propane orifices, 40 | Main burner #53 (0.0595"), low-rate #50 (0.070") |
| Propane input, 35 | 23,000 BTU/hr high, 17,000 BTU/hr low |
| Propane input, 40 | 26,000 BTU/hr high, 19,000 BTU/hr low |
| Propane pressures | Manifold 10.0" WC; inlet 11.0" to 13.0" WC |
| Altitude | Orifices sized for 0 to 2,000 ft in the USA |
| Instructions | P/N 900888-00 |
| Brand | Astria |
Questions people ask us
Which kit do I need?
Match the kit to the fireplace: GCKGDLX35NP for the Gemini DLX 35 and GCKGDLX40NP for the Gemini DLX 40. The size is in the model number on the rating label, for example GeminiDLX35.
What does the conversion involve?
The installer swaps the main burner orifice and the low-rate orifice in the valve, sets the regulator and pilot for propane, leak tests every joint, checks the inlet and manifold pressures with a manometer, sets the air shutter to a 1/8 inch gap for propane and fills out the conversion sticker.
What is the heat output on propane?
Astria rates the Gemini DLX 35 at 23,000 BTU/hr high and 17,000 low, and the Gemini DLX 40 at 26,000 high and 19,000 low, on propane.
I live at altitude. Does that change anything?
The orifices are sized for 0 to 2,000 feet in the USA. Above that, Astria calls for a 4 percent derate per 1,000 feet, recorded on a deration sticker. Your installer will handle it.
Not sure which model you have?
Send us the model number from your rating label and we will confirm the kit.
Goes with this
Manuals and warranty
Warranty terms come from Astria and depend on the product. Read the manual and the warranty for your model before you order.
Our warranty library· Gemini DLX natural gas to propane conversion instructions (PDF)Ask us before you order