Authorized Heatstar Dealer

All the heat stays in the room.

Vent free means no chimney, no flue and no hole in the wall. Nothing goes outside, so nothing you paid for goes outside either.

No venting required Natural gas or propane 5 year warranty
Heatstar outdoor heater
No venting Nothing cut into the wall
Gas or propane Built for one or the other
ODS standard Shuts down on low oxygen
5 years On every vent free heater

Start here

Where is the heat going?

Heatstar make three different answers to that, and they are not interchangeable. Pick the one that matches the space before you worry about size.

Check the gas first. Every heater here is built for either natural gas or propane and the two are not interchangeable. Confirm what runs to the spot before you choose anything else.

The first decision

Radiant or blue flame?

Same brand, same BTU ratings, same wall. What changes is what the heat lands on, and it changes how the room feels more than the size does.

Radiant

Infrared. Warms objects and people, not the air.

  • You feel it almost immediately, the way you feel sun
  • Holds up better in a room with drafts or a high ceiling
  • Heatstar list these as Infrared on the spec sheet

Take this one if the room has a lot in it, or the air moves.

Blue Flame

Convection. Heats the air, which then heats the room.

  • Takes longer to come up, then sits more evenly
  • Suits a room that is closed up and reasonably sealed
  • A tube burner uses the natural rise of the burn to circulate

Take this one if the room is open and fairly empty.

Heatstar's own guidance: a room with a lot in it suits radiant, because the heat lands on the objects. An open room suits blue flame, because there is more air to move.

Warms you, not the air

Vent Free Radiant Heaters

Infrared heat off a ceramic tile burner. You feel it the moment it lights, the way you feel sun through a window, and it keeps working in a room where the air moves.

10,000 to 30,000 BTUNatural gas or propaneWall or floor mount

Warms the whole room

Vent Free Blue Flame Heaters

A blue flame tube burner that heats the air and lets it circulate on its own. Slower to come up than radiant, then noticeably more even once it is there.

10,000 to 30,000 BTUNatural gas or propaneWall or floor mount

Size it properly

How big is the room?

Give us the three measurements and we will tell you the BTU to start with, and whether the room has enough air to burn vent free in at all. That second one is the part most sites skip.

Out of the way

Overhead Radiant Heaters

High intensity radiant mounted ten to twelve feet up, aimed down at the floor and at the people on it. The heat goes where the work is instead of collecting at the ceiling.

40,000 BTUMounts 10 to 12 ftNatural gas or propane

Heat where you are

Portable and Workshop Heaters

Radiant heat you can carry to the job, from a 22,000 BTU workshop unit up to 125,000 BTU for an open bay. The big one runs off a 100 lb tank and covers serious ground.

22,000 to 125,000 BTUTank or line fedNothing to install

Keep it running

Parts and Accessories

The oxygen depletion sensor pilot, the ignitor module, the high limit switch and the blower kit. Genuine Heatstar, so it fits the heater you already own.

ODS pilotsIgnitor modulesBlower kits

Before you buy

What vent free asks of the room

Vent free heaters put their combustion air and their exhaust into the room they heat. That is why they waste nothing, and it is also why the room has rules. Heatstar do not sell these into California or Canada, and some local codes go further, so check with your building department before you order.

ODS

It watches the air for you

Every one of these ships with an Oxygen Depletion Sensor on the pilot. If the fresh air in the room runs low, the sensor shuts the heater off. It is not an option you add, it is factory standard.

50cu ft

Per 1,000 BTU of heater

Heatstar count a space as unconfined when it holds at least fifty cubic feet of air for every 1,000 BTU. Under that the manual asks for extra combustion air. The sizer above does this sum for you.

4,500ft

Elevation limit

Above about 4,500 feet the thinner air can trip the pilot and the oxygen sensor and shut the heater down. Worth knowing before you ship one up a mountain.

Not sure it suits the room?

Tell us the length, width and ceiling height, whether you have natural gas or propane at the spot, and what the room is used for. That is enough for us to tell you the heater, the BTU and whether the space needs any extra ventilation first.

631-678-6506