{"product_id":"superior-htflo-dv45-heatflo-kit-45-inch-linear","title":"Superior HeatFlo Kit for DRL2045, DRL3545 and 45\" Compass | HTFLO-DV45","description":"\u003cp\u003e\u003cb\u003eThe Superior HTFLO-DV45 (cat. no. F4454) is the HeatFlo kit for 45\" linear direct-vent fireplaces, listed by IHP for DRL2045, DRL3545 and 45\" Compass.\u003c\/b\u003e HeatFlo redirects the convective heat from the front of the fireplace to a register higher on the wall, which allows a TV closer to the fireplace or in a recessed pocket above it. It is installed at the time the fireplace is installed.\u003c\/p\u003e\n\u003ch2\u003eAt a glance\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat register\u003c\/strong\u003e: Moves heat up the wall\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTV 12\" above\u003c\/strong\u003e: Flush wall minimum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e76\" minimum\u003c\/strong\u003e: Base to register opening\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstaller fitted\u003c\/strong\u003e: At fireplace install\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDetails\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eHTFLO-DV45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCat. no.\u003c\/th\u003e\n\u003ctd\u003eF4454\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit name\u003c\/th\u003e\n\u003ctd\u003eHeatflo Kit for 45\" Units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFits\u003c\/th\u003e\n\u003ctd\u003eSuperior DRL2000 45 and DRL3500 45 (DRL2045, DRL3545); Astria Compass 45 and Compass DLX 45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit contents\u003c\/th\u003e\n\u003ctd\u003e1 register assembly, 1 register trim, 4 flex pipes 4-1\/2\" x 24\" (stretch to 70\"), 8 gear clamps, 2 register support brackets, 18 screws, 4 collar mounting plates, 4 small collars, 4 large collars, 1 angled hood\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRegister opening\u003c\/th\u003e\n\u003ctd\u003eAt least 76\" above the fireplace base, no more than 20 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTV, flush wall\u003c\/th\u003e\n\u003ctd\u003eAt least 12\" above the fireplace opening, 3\" below the vent opening\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecessed pocket\u003c\/th\u003e\n\u003ctd\u003eAt least 18\" above the opening, 5-1\/2\" below, 3-1\/2\" max depth, 3\" clearance on all sides\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCeiling\u003c\/th\u003e\n\u003ctd\u003eVent opening at least 4\" below the ceiling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearance\u003c\/th\u003e\n\u003ctd\u003e1\" minimum to combustibles around the flex pipes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eSuperior (Innovative Hearth Products)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003ePlan it at the framing stage.\u003c\/strong\u003e IHP says the kit must be installed by a qualified installer, service agency or gas supplier when the fireplace is installed. Never cover the register or place objects in front of it, and keep the register at least 76\" above the floor.\u003c\/p\u003e\n\u003ch2\u003eQuestions people ask us\u003c\/h2\u003e\u003ch3\u003eWhat does a HeatFlo kit do?\u003c\/h3\u003e\u003cp\u003eIt takes the convective heat that would leave the front of the fireplace and sends it through flex pipes to a \u003cb\u003eregister higher on the wall\u003c\/b\u003e. That lets a TV sit closer above the fireplace or in a recessed pocket.\u003c\/p\u003e\u003ch3\u003eHow close can the TV be?\u003c\/h3\u003e\u003cp\u003eOn a flush wall IHP gives \u003cb\u003e12 inches\u003c\/b\u003e above the fireplace opening as the minimum, and 18 inches for a recessed pocket. Follow the TV maker's heat limits too. Most TV makers advise against mounting above a heat source.\u003c\/p\u003e\u003ch3\u003eCan I add it to a finished wall?\u003c\/h3\u003e\u003cp\u003eIt is meant to go in when the fireplace is installed and framed. The framing dimensions change with the kit, so plan it before the wall is closed.\u003c\/p\u003e\u003ch3\u003eWhat is in the box?\u003c\/h3\u003e\u003cp\u003eA register assembly and trim, four \u003cb\u003e4-1\/2 inch\u003c\/b\u003e flex pipes that stretch to 70 inches, clamps, brackets, collars, screws and an angled hood that replaces the flat hood.\u003c\/p\u003e\u003ch3\u003eIs it right for my fireplace?\u003c\/h3\u003e\u003cp\u003eThe model number is on the rating label of the fireplace. \u003ca href=\"\/pages\/contact-us\"\u003eSend it to us\u003c\/a\u003e and we will check the part against the parts list before you order.\u003c\/p\u003e","brand":"Superior","offers":[{"title":"Default Title","offer_id":67636511080722,"sku":"HTFLO-DV45","price":674.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/2279\/1186\/files\/superior-htflo-dv45-heatflo-kit-45-inch-linear.png?v=1792699855","url":"https:\/\/www.aquaterrabackyard.com\/products\/superior-htflo-dv45-heatflo-kit-45-inch-linear","provider":"Aqua Terra Backyard","version":"1.0","type":"link"}