{"product_id":"astria-gemini-dlx-natural-gas-to-propane-conversion-kit","title":"Astria Gemini DLX Natural Gas to Propane Conversion Kit","description":"\u003cp\u003e\u003cb\u003eThe Astria GCKGDLX35NP and GCKGDLX40NP are natural gas to propane conversion kits for the Gemini DLX 35 and Gemini DLX 40 direct vent gas fireplaces with the EcoFlow electronic valve.\u003c\/b\u003e Each kit has the propane main burner orifice and low-rate orifice for its size, plus the conversion sticker and form. Catalog numbers F3673 (35) and F3675 (40). A qualified service agency must install it.\u003c\/p\u003e\n\u003ch2\u003eAt a glance\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNG to LP\u003c\/strong\u003e: Natural gas to propane\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGemini DLX 35 or 40\u003c\/strong\u003e: One kit per size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEcoFlow valve\u003c\/strong\u003e: Electronic ignition models\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQualified service agency\u003c\/strong\u003e: Required by Astria\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDetails\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eGCKGDLX35NP\u003c\/th\u003e\n\u003ctd\u003eCatalog F3673, for the GeminiDLX35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGCKGDLX40NP\u003c\/th\u003e\n\u003ctd\u003eCatalog F3675, for the GeminiDLX40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConversion\u003c\/th\u003e\n\u003ctd\u003eNatural gas to propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eValve\u003c\/th\u003e\n\u003ctd\u003eEcoFlow electronic ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContents\u003c\/th\u003e\n\u003ctd\u003eMain burner orifice, low-rate orifice, conversion sticker, conversion sticker form\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePropane orifices, 35\u003c\/th\u003e\n\u003ctd\u003eMain burner #54 (0.055\"), low-rate #50 (0.070\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePropane orifices, 40\u003c\/th\u003e\n\u003ctd\u003eMain burner #53 (0.0595\"), low-rate #50 (0.070\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePropane input, 35\u003c\/th\u003e\n\u003ctd\u003e23,000 BTU\/hr high, 17,000 BTU\/hr low\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePropane input, 40\u003c\/th\u003e\n\u003ctd\u003e26,000 BTU\/hr high, 19,000 BTU\/hr low\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePropane pressures\u003c\/th\u003e\n\u003ctd\u003eManifold 10.0\" WC; inlet 11.0\" to 13.0\" WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003eOrifices sized for 0 to 2,000 ft in the USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstructions\u003c\/th\u003e\n\u003ctd\u003eP\/N 900888-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eAstria\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eA qualified service agency must install this kit.\u003c\/strong\u003e Astria requires installation by a qualified service agency to its instructions, with the gas off, the power off at the breaker and the fireplace cold. A licensed gas professional should make the gas connection to the instructions and local codes.\u003c\/p\u003e\n\u003ch2\u003eQuestions people ask us\u003c\/h2\u003e\u003ch3\u003eWhich kit do I need?\u003c\/h3\u003e\u003cp\u003eMatch the kit to the fireplace: \u003cb\u003eGCKGDLX35NP\u003c\/b\u003e for the Gemini DLX 35 and \u003cb\u003eGCKGDLX40NP\u003c\/b\u003e for the Gemini DLX 40. The size is in the model number on the rating label, for example GeminiDLX35.\u003c\/p\u003e\u003ch3\u003eWhat does the conversion involve?\u003c\/h3\u003e\u003cp\u003eThe installer swaps the \u003cb\u003emain burner orifice\u003c\/b\u003e and the \u003cb\u003elow-rate orifice\u003c\/b\u003e in the valve, sets the regulator and pilot for propane, leak tests every joint, checks the inlet and manifold pressures with a manometer, sets the air shutter to a \u003cb\u003e1\/8 inch\u003c\/b\u003e gap for propane and fills out the conversion sticker.\u003c\/p\u003e\u003ch3\u003eWhat is the heat output on propane?\u003c\/h3\u003e\u003cp\u003eAstria rates the Gemini DLX 35 at \u003cb\u003e23,000 BTU\/hr high and 17,000 low\u003c\/b\u003e, and the Gemini DLX 40 at \u003cb\u003e26,000 high and 19,000 low\u003c\/b\u003e, on propane.\u003c\/p\u003e\u003ch3\u003eI live at altitude. Does that change anything?\u003c\/h3\u003e\u003cp\u003eThe orifices are sized for \u003cb\u003e0 to 2,000 feet\u003c\/b\u003e in the USA. Above that, Astria calls for a 4 percent derate per 1,000 feet, recorded on a deration sticker. Your installer will handle it.\u003c\/p\u003e\u003ch3\u003eNot sure which model you have?\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"\/pages\/contact-us\"\u003eSend us the model number\u003c\/a\u003e from your rating label and we will confirm the kit.\u003c\/p\u003e","brand":"Astria","offers":[{"title":"Gemini DLX 35","offer_id":67636514586898,"sku":"GCKGDLX35NP","price":137.0,"currency_code":"USD","in_stock":true},{"title":"Gemini DLX 40","offer_id":67636514619666,"sku":"GCKGDLX40NP","price":137.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/2279\/1186\/files\/astria-gemini-dlx-natural-gas-to-propane-conversion-kit.png?v=1792700007","url":"https:\/\/www.aquaterrabackyard.com\/products\/astria-gemini-dlx-natural-gas-to-propane-conversion-kit","provider":"Aqua Terra Backyard","version":"1.0","type":"link"}