{"title":"Enervex","description":null,"products":[{"product_id":"enervex-rsd-dilution-bolts","title":"Enervex RSD Dilution Bolts, Set of 4, for RS and GSV Chimney Fans | RSD","description":"\u003cp\u003e\u003cb\u003eEnervex RSD dilution bolts, sold as a set of 4, lift an Enervex chimney fan slightly off its base so outside air mixes in and cools the flue gas.\u003c\/b\u003e Enervex uses them where flue gas runs above 575°F or where vibration is a problem, such as solid fuel boilers. They fit the holes in the corners of the fan's base plate. Part number RSD.\u003c\/p\u003e\n\u003ch2\u003eAt a glance\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAbove 575°F\u003c\/strong\u003e: Flue gas applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDilution air\u003c\/strong\u003e: Cools the flue gas at the fan\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnti-vibration\u003c\/strong\u003e: Vibration free mounting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable height\u003c\/strong\u003e: Two nuts on a spacing screw\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDetails\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eQuantity\u003c\/th\u003e\n\u003ctd\u003eSet of 4 dilution bolts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlso called\u003c\/th\u003e\n\u003ctd\u003eAnti-vibration dampers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUse\u003c\/th\u003e\n\u003ctd\u003eFlue gas above 575°F (300°C), or where vibration is a problem\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFits\u003c\/th\u003e\n\u003ctd\u003eHoles in the corners of the base plate of Enervex chimney fans; the RS and GSV manuals call for them in the outer base holes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdjustment\u003c\/th\u003e\n\u003ctd\u003eHeight set with two nuts on a spacing screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMineral wool plate\u003c\/th\u003e\n\u003ctd\u003eNot needed when the fan sits on RSDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eEnervex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eDilution bolts reduce fan capacity.\u003c\/strong\u003e Enervex notes that a fan on dilution bolts moves less air, so check the sizing with the factory, and the fan must run whenever there is combustion.\u003c\/p\u003e\n\u003ch2\u003eQuestions people ask us\u003c\/h2\u003e\u003ch3\u003eWhen do I need dilution bolts?\u003c\/h3\u003e\u003cp\u003eWhen the flue gas at the fan runs hotter than the fan is rated for, or when the fan vibrates on its base. Enervex names \u003cb\u003e575°F\u003c\/b\u003e as the point for flue gas.\u003c\/p\u003e\u003ch3\u003eWhat is included?\u003c\/h3\u003e\u003cp\u003eEnervex part RSD is a \u003cb\u003eset of 4\u003c\/b\u003e dilution bolts. They fit the holes in the corners of the fan's base plate, and you set the height with the two nuts on each spacing screw.\u003c\/p\u003e\u003ch3\u003eWhich fans do they fit?\u003c\/h3\u003e\u003cp\u003eThey fit the corner holes in the base plate of Enervex chimney fans. The \u003ca href=\"\/products\/enervex-rs-chimney-fan\"\u003eRS\u003c\/a\u003e and \u003ca href=\"\/products\/enervex-gsv-012-pizza-oven-fan\"\u003eGSV\u003c\/a\u003e manuals call for them in the outer base holes.\u003c\/p\u003e\u003ch3\u003eWill they change how my fan performs?\u003c\/h3\u003e\u003cp\u003eYes. Dilution bolts \u003cb\u003ereduce capacity\u003c\/b\u003e, and a larger fan may be needed. \u003ca href=\"\/pages\/contact-us\"\u003eSend us\u003c\/a\u003e your fan model and appliance and we will check it with Enervex.\u003c\/p\u003e","brand":"Enervex","offers":[{"title":"Default Title","offer_id":67630596063506,"sku":"RSD","price":79.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/2279\/1186\/files\/enervex-rsd-dilution-bolts.png?v=1792561056"},{"product_id":"enervex-adc100-fan-and-damper-control","title":"Enervex ADC100 Fan and Damper Control with Proven Draft Switch | ADC100","description":"\u003cp\u003e\u003cb\u003eThe Enervex ADC100 is an indoor fan and damper control for Enervex RS and GSV fans, supplied with a PDS proven draft switch.\u003c\/b\u003e It sets the fan speed, opens a damper, and only lets the appliance fire once the switch proves there is draft. It is the control in Enervex's EcoDamper system with an RS fan and MFD damper. Part number ADC100.\u003c\/p\u003e\n\u003ch2\u003eAt a glance\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable speed\u003c\/strong\u003e: 10 to 120 VAC fan output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePDS included\u003c\/strong\u003e: Proves draft before firing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDamper relay\u003c\/strong\u003e: With damper prove input\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1 x 120 VAC\u003c\/strong\u003e: Indoor installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDetails\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eADC100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUse\u003c\/th\u003e\n\u003ctd\u003eDraft control for a fireplace where modulation is not required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWorks with\u003c\/th\u003e\n\u003ctd\u003eEnervex RS and GSV fans; MFD damper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply\u003c\/th\u003e\n\u003ctd\u003e1 x 120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e10 to 120 VAC or 0 to 10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelays\u003c\/th\u003e\n\u003ctd\u003eTwo control relays, max 120 VAC \/ 8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFunctions\u003c\/th\u003e\n\u003ctd\u003eVariable fan speed, adjustable post purge (0 to 3 minutes), damper relay with prove input, gas valve or ignition interlock, interlock for up to two appliances\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIncluded\u003c\/th\u003e\n\u003ctd\u003eControl, PDS1 proven draft switch, stack probe, 6 ft silicone tubing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eNEMA 1, ABS plastic, indoor only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e9.6 x 6.3 x 3.5 in., 2.6 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-4°F to 122°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eEnervex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eIndoor installation by a qualified person.\u003c\/strong\u003e Enervex's manual calls for installation and wiring by a qualified person to local codes or the National Electrical Code. We recommend a licensed electrician, and a licensed gas professional for any gas valve connection.\u003c\/p\u003e\n\u003ch2\u003eQuestions people ask us\u003c\/h2\u003e\u003ch3\u003eWhat fans does it work with?\u003c\/h3\u003e\u003cp\u003eEnervex lists the ADC100 for its \u003cb\u003eRS\u003c\/b\u003e and \u003cb\u003eGSV\u003c\/b\u003e fans. It runs single phase 120V fans directly; three phase fans need a VFD. See the \u003ca href=\"\/products\/enervex-rs-chimney-fan\"\u003eRS chimney fan\u003c\/a\u003e.\u003c\/p\u003e\u003ch3\u003eIs the proven draft switch included?\u003c\/h3\u003e\u003cp\u003eYes. It ships with the \u003cb\u003ePDS1 proven draft switch\u003c\/b\u003e, a stack probe and 6 ft of silicone tubing. The tubing can be extended to 25 ft with 1\/4 in. rigid tubing, not supplied.\u003c\/p\u003e\u003ch3\u003eCan it run a chimney top damper?\u003c\/h3\u003e\u003cp\u003eYes. It has a damper relay and a damper prove input, and it is the control Enervex pairs with the \u003ca href=\"\/products\/enervex-mfd-mechanical-fireplace-damper-120v\"\u003eMFD mechanical fireplace damper\u003c\/a\u003e.\u003c\/p\u003e\u003ch3\u003eCan it go outside?\u003c\/h3\u003e\u003cp\u003eNo. The ADC100 has a NEMA 1 enclosure and is for \u003cb\u003eindoor installation only\u003c\/b\u003e.\u003c\/p\u003e","brand":"Enervex","offers":[{"title":"Default Title","offer_id":67630598226194,"sku":"ADC100","price":1139.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/2279\/1186\/files\/enervex-adc100-fan-and-damper-control.png?v=1792561090"},{"product_id":"enervex-ebc24x-motor-power-relay","title":"Enervex EBC 24X Motor Power Relay for Multiple Fans | EBC24X","description":"\u003cp\u003e\u003cb\u003eThe Enervex EBC 24X is a motor power relay that lets one Enervex main control run several single phase fans.\u003c\/b\u003e One fan connects to the main control and the others connect through one or more EBC 24X units, which follow the main control's 0 to 10 VDC signal so every fan runs at the same speed. Part number EBC24X.\u003c\/p\u003e\n\u003ch2\u003eAt a glance\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple fans\u003c\/strong\u003e: From one main control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0 to 10 VDC in\u003c\/strong\u003e: 10 to 120 VAC out\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1 x 120 VAC\u003c\/strong\u003e: 6.3 A rated supply\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED on every terminal\u003c\/strong\u003e: For easy troubleshooting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDetails\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eEBC24X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUse\u003c\/th\u003e\n\u003ctd\u003eExternal motor speed control for additional single phase fans\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain controls listed by Enervex\u003c\/th\u003e\n\u003ctd\u003eBDC8, EBC12, EBC14, EBC24, MEC18, MEC24, EBC30, EBC31\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply\u003c\/th\u003e\n\u003ctd\u003e1 x 120 VAC, 6.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput signal\u003c\/th\u003e\n\u003ctd\u003e0 to 10 VDC from the main control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e10 to 120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003ePolycarbonate, indoor installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e6.9 x 6.9 x 4.33 in., 2.8 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-4°F to 122°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eListings\u003c\/th\u003e\n\u003ctd\u003eUL 60947-4-1 and CSA C22.2 No. 14-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eEnervex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eInstall indoors and have it wired by a qualified person.\u003c\/strong\u003e Enervex's manual calls for indoor installation, preferably in the boiler room, with wiring by a qualified person to applicable codes, and the unit grounded. We recommend a licensed electrician.\u003c\/p\u003e\n\u003ch2\u003eQuestions people ask us\u003c\/h2\u003e\u003ch3\u003eWhich controls does it work with?\u003c\/h3\u003e\u003cp\u003eEnervex lists the \u003cb\u003eBDC8, EBC12, EBC14, EBC24, MEC18, MEC24, EBC30 and EBC31\u003c\/b\u003e. If your system uses another control, \u003ca href=\"\/pages\/contact-us\"\u003esend us\u003c\/a\u003e the model and we will confirm with Enervex before you order.\u003c\/p\u003e\u003ch3\u003eHow many fans can one relay run?\u003c\/h3\u003e\u003cp\u003eIt depends on the fan model and its current draw. Enervex's manual has a table for this, so \u003ca href=\"\/pages\/contact-us\"\u003esend us\u003c\/a\u003e your fan models and we will work out how many relays you need.\u003c\/p\u003e\u003ch3\u003eCan it be mounted outdoors?\u003c\/h3\u003e\u003cp\u003eNo. Enervex says it must be installed \u003cb\u003einside\u003c\/b\u003e, preferably in the boiler room.\u003c\/p\u003e","brand":"Enervex","offers":[{"title":"Default Title","offer_id":67630599962898,"sku":"EBC24X","price":1576.67,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/2279\/1186\/files\/enervex-ebc24x-motor-power-relay.png?v=1792561128"},{"product_id":"enervex-gsv-012-pizza-oven-fan","title":"Enervex GSV 012 Pizza Oven Fan, 120V","description":"\u003cp\u003e\u003cb\u003eThe Enervex GSV 012 is a 120 volt pizza oven exhaust fan rated at 875 CFM, built for gas and wood fired ovens.\u003c\/b\u003e It mounts at the top of the chimney or grease duct, vertically or on a side wall, and its axial vane design is self cleaning. The cast aluminum housing opens on a hinge for cleaning and service. Part number GSV-012.\u003c\/p\u003e\n\u003ch2\u003eAt a glance\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e875 CFM\u003c\/strong\u003e: At 0.0 in. static pressure\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e575°F rating\u003c\/strong\u003e: Gas or solid fuel ovens\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e120V, 1.4 A\u003c\/strong\u003e: 1600 RPM, variable speed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 705 listed\u003c\/strong\u003e: Including Supplement SC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eGSV 012 (part number GSV-012)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUse\u003c\/th\u003e\n\u003ctd\u003ePizza ovens on natural gas, LP gas or solid fuel, through a hood or a direct chimney connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCapacity\u003c\/th\u003e\n\u003ctd\u003e875 CFM at 0.0 in. static pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical\u003c\/th\u003e\n\u003ctd\u003e1 x 120 VAC, 1.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSpeed\u003c\/th\u003e\n\u003ctd\u003e1600 RPM, variable speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor\u003c\/th\u003e\n\u003ctd\u003eSingle phase, split capacitor, totally enclosed, IP54, sealed ball bearings, thermal overload protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e46 lbs (18 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimension B x B (per Enervex drawing)\u003c\/th\u003e\n\u003ctd\u003e15.37 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConstruction\u003c\/th\u003e\n\u003ctd\u003e3\/16 in. cast aluminum housing in grey hammer paint, stainless steel axial vanes, vertical discharge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature rating\u003c\/th\u003e\n\u003ctd\u003e575°F (300°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard equipment\u003c\/th\u003e\n\u003ctd\u003eJunction box with cover and conduit, bird screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOptional equipment\u003c\/th\u003e\n\u003ctd\u003e5 or 8 amp fan speed control, neoprene gasket, roof curb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eListings\u003c\/th\u003e\n\u003ctd\u003eETL listed to UL 705, UL 705 Supplement SC and ULC-S645-93\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eEnervex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eRun the fan whenever the oven is in use.\u003c\/strong\u003e Enervex's manual says to set the fan to full speed before lighting, then turn it down once the fire is established. Keep it at least 3 ft from any forced air inlet within 10 ft and 4 ft from doors and windows. Installation and wiring must be done by a qualified person to local codes or the National Electrical Code; we recommend a licensed electrician.\u003c\/p\u003e\n\u003ch2\u003eQuestions people ask us\u003c\/h2\u003e\u003ch3\u003eDoes it work with a wood fired oven?\u003c\/h3\u003e\u003cp\u003eYes. Enervex lists the GSV for natural gas, LP gas and \u003cb\u003esolid fuel\u003c\/b\u003e, and it is built to handle the creosote that wood produces.\u003c\/p\u003e\u003ch3\u003eHow do I mount it?\u003c\/h3\u003e\u003cp\u003eIt mounts on a \u003ca href=\"\/products\/enervex-sca-steel-chimney-adapter\"\u003esteel chimney adapter (SCA)\u003c\/a\u003e or on a roof curb, sealed watertight without blocking the four drain holes in the base.\u003c\/p\u003e\u003ch3\u003eIs a speed control included?\u003c\/h3\u003e\u003cp\u003eThe standard equipment is the junction box and bird screen. Enervex offers a 5 or 8 amp fan speed control as an option, and the \u003ca href=\"\/products\/enervex-adc100-fan-and-damper-control\"\u003eADC100 control\u003c\/a\u003e also works with GSV fans.\u003c\/p\u003e\u003ch3\u003eHow often does it need cleaning?\u003c\/h3\u003e\u003cp\u003eEnervex suggests checking every \u003cb\u003e2 weeks\u003c\/b\u003e for the first couple of months to see how fast creosote builds, and cleaning wood fired commercial units at least \u003cb\u003eonce a month\u003c\/b\u003e unless use shows less is enough. Clean all parts when deposits pass 1\/16 in.\u003c\/p\u003e\u003ch3\u003eIs the GSV 012 the right size for my oven?\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"\/pages\/contact-us\"\u003eSend us\u003c\/a\u003e the oven model, fuel and flue size and we will check the fan size with Enervex before you order.\u003c\/p\u003e","brand":"Enervex","offers":[{"title":"Default Title","offer_id":67630600880402,"sku":"GSV-012","price":4015.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/2279\/1186\/files\/enervex-gsv-012-pizza-oven-fan.png?v=1792561172"},{"product_id":"enervex-mfd-mechanical-fireplace-damper-120v","title":"Enervex MFD Mechanical Fireplace Damper for RS014 and RS016, 120V","description":"\u003cp\u003e\u003cb\u003eThe Enervex MFD is a motorized chimney top damper that sits between a steel chimney and an Enervex RS fan, here with a 120 volt actuator in 12 in. and 14 in. sizes for the RS014 and RS016.\u003c\/b\u003e It keeps heat from escaping up the chimney when the fireplace is off and stops downdraft. It is interlocked to an ADC100 or ADC150 control, so it opens only when the fireplace is in use and the fan is running. Part numbers 216.0200.1212 (12 in.) and EXH2914-120 (14 in.).\u003c\/p\u003e\n\u003ch2\u003eAt a glance\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChimney top damper\u003c\/strong\u003e: Mounts under the RS fan\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e120 VAC actuator\u003c\/strong\u003e: 90° in 15 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFails open\u003c\/strong\u003e: On electrical or mechanical failure\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eADC100 or ADC150\u003c\/strong\u003e: Interlock required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDetails\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003ePart numbers\u003c\/th\u003e\n\u003ctd\u003e216.0200.1212 (12 in.), EXH2914-120 (14 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFits fans\u003c\/th\u003e\n\u003ctd\u003eEnervex RS014 and RS016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUse\u003c\/th\u003e\n\u003ctd\u003eGas fireplaces, chimney top installation on a steel chimney\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuator\u003c\/th\u003e\n\u003ctd\u003e120 VAC brushless motor, 54 in-lbs (6 Nm), 90° in 15 seconds, 2 end switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFail safe\u003c\/th\u003e\n\u003ctd\u003eDamper opens on electrical or mechanical failure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e12 in. dimensions\u003c\/th\u003e\n\u003ctd\u003eA 11.87 in., B x B 19.70 in., C 20.80 in., D 2.61 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e14 in. dimensions\u003c\/th\u003e\n\u003ctd\u003eA 13.87 in., B x B 19.70 in., C 21.80 in., D 2.77 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControls\u003c\/th\u003e\n\u003ctd\u003eInterlocked to an Enervex ADC100 or ADC150 control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eEnervex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eFor gas fireplaces with an Enervex fan and control.\u003c\/strong\u003e The damper must be interlocked with an ADC100 or ADC150 control. Installation and wiring must be done by qualified persons to local codes or the National Electrical Code, and the unit must be grounded. We recommend a licensed electrician for the wiring.\u003c\/p\u003e\n\u003ch2\u003eQuestions people ask us\u003c\/h2\u003e\u003ch3\u003eHow does it mount?\u003c\/h3\u003e\u003cp\u003eThe collar slides into the top of the steel chimney until the damper rests on its stop flange. The \u003ca href=\"\/products\/enervex-rs-chimney-fan\"\u003eRS fan\u003c\/a\u003e then bolts onto the damper's fan adapter, so the damper sits between the chimney and the fan.\u003c\/p\u003e\u003ch3\u003eWhich size do I order?\u003c\/h3\u003e\u003cp\u003eOrder by the chimney size: \u003cb\u003e12 in.\u003c\/b\u003e or \u003cb\u003e14 in.\u003c\/b\u003e Both sizes listed here are for the RS014 and RS016 fans.\u003c\/p\u003e\u003ch3\u003eWhat happens if the power goes out?\u003c\/h3\u003e\u003cp\u003eThe actuator uses a fail safe system that \u003cb\u003eopens the damper\u003c\/b\u003e on an electrical or mechanical failure, so the flue is not left closed.\u003c\/p\u003e\u003ch3\u003eWhat control do I need with it?\u003c\/h3\u003e\u003cp\u003eAn Enervex \u003ca href=\"\/products\/enervex-adc100-fan-and-damper-control\"\u003eADC100\u003c\/a\u003e or ADC150. The control opens the damper and starts the fan, then releases the gas valve once there is enough draft. Enervex calls the ADC100, RS fan and MFD combination the EcoDamper system.\u003c\/p\u003e\u003ch3\u003eDoes it work with a wood fireplace?\u003c\/h3\u003e\u003cp\u003eThis MFD is for \u003cb\u003egas fireplaces\u003c\/b\u003e. \u003ca href=\"\/pages\/contact-us\"\u003eSend us your setup\u003c\/a\u003e if you burn wood and we will look at the options with Enervex.\u003c\/p\u003e","brand":"Enervex","offers":[{"title":"12 in.","offer_id":67630600913170,"sku":"216.0200.1212","price":3080.0,"currency_code":"USD","in_stock":true},{"title":"14 in.","offer_id":67630600945938,"sku":"EXH2914-120","price":3182.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/2279\/1186\/files\/enervex-mfd-mechanical-fireplace-damper-120v.png?v=1792561207"},{"product_id":"enervex-asca-steel-chimney-adapter","title":"Enervex ASCA Steel Chimney Adapter for Air Cooled Chimneys","description":"\u003cp\u003e\u003cb\u003eThe Enervex ASCA is a stainless steel adapter for mounting an Enervex chimney fan on a double walled, air cooled steel chimney.\u003c\/b\u003e A square plate supports the fan, a 5 inch collar slides into the chimney, and spacers underneath let air keep moving between the inner and outer walls. Offered here as 222.0400.2008 for an 8 in. flue and 222.0400.3010 for a 10 in. flue.\u003c\/p\u003e\n\u003ch2\u003eAt a glance\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir cooled chimneys\u003c\/strong\u003e: Keeps the wall space vented\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e316L stainless\u003c\/strong\u003e: 16 gauge\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5 in. collar\u003c\/strong\u003e: No external fastening needed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e8 in. or 10 in.\u003c\/strong\u003e: Flue sizes listed here\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDetails\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003ePart numbers\u003c\/th\u003e\n\u003ctd\u003e222.0400.2008 (8 in. flue, RS 009 size), 222.0400.3010 (10 in. flue, RS 012 or RS 014 size)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUse\u003c\/th\u003e\n\u003ctd\u003eMounting an Enervex RS or RSHT chimney fan on a round, double walled, air cooled steel chimney\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlue size\u003c\/th\u003e\n\u003ctd\u003eThe inside diameter of the chimney\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCollar\u003c\/th\u003e\n\u003ctd\u003e5 in., outside diameter 1\/8 in. smaller than the chimney inside diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVentilation\u003c\/th\u003e\n\u003ctd\u003eSpacers under the plate let air circulate between the inner and outer walls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003e16 gauge 316L stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation\u003c\/th\u003e\n\u003ctd\u003eSlides into the chimney for a tight fit, no tools needed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eEnervex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eOrder by the inside diameter of the chimney.\u003c\/strong\u003e The collar is made 1\/8 in. under the inside diameter. For a single or double wall steel chimney that is not air cooled, use the SCA adapter.\u003c\/p\u003e\n\u003ch2\u003eQuestions people ask us\u003c\/h2\u003e\u003ch3\u003eHow do I know if my chimney is air cooled?\u003c\/h3\u003e\u003cp\u003eAn air cooled chimney has an open space between its inner and outer walls that air moves through. The chimney maker's label or manual will say so. If you are unsure, \u003ca href=\"\/pages\/contact-us\"\u003esend us\u003c\/a\u003e the chimney brand and model.\u003c\/p\u003e\u003ch3\u003eWhich fan does each size fit?\u003c\/h3\u003e\u003cp\u003eIn Enervex's chart the \u003cb\u003e8 in.\u003c\/b\u003e adapter is in the RS 009 group and the \u003cb\u003e10 in.\u003c\/b\u003e adapter is in the RS 012 and RS 014 group. Enervex describes the ASCA for its RS and RSHT fans.\u003c\/p\u003e\u003ch3\u003eWhat if my chimney is not air cooled?\u003c\/h3\u003e\u003cp\u003eUse the \u003ca href=\"\/products\/enervex-sca-steel-chimney-adapter\"\u003eSCA steel chimney adapter\u003c\/a\u003e, which covers single and double wall steel chimneys in more sizes.\u003c\/p\u003e","brand":"Enervex","offers":[{"title":"RS 009 \/ 8 in.","offer_id":67630601404690,"sku":"222.0400.2008","price":619.0,"currency_code":"USD","in_stock":true},{"title":"RS 012 or RS 014 \/ 10 in.","offer_id":67630601437458,"sku":"222.0400.3010","price":651.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/2279\/1186\/files\/enervex-asca-steel-chimney-adapter.png?v=1792561247"},{"product_id":"enervex-rs-chimney-fan","title":"Enervex RS Chimney Fan for Gas Fireplaces, 120V","description":"\u003cp\u003e\u003cb\u003eThe Enervex RS is a chimney top exhaust fan for gas and oil appliances, offered here in two sizes: RS014 and RS016.\u003c\/b\u003e It sits on top of the chimney and pulls flue gases up and out, then discharges them sideways like a standard chimney cap. Enervex builds it for gas fireplaces, stoves, BBQs and pizza ovens with draft problems, and it runs on 120 volts with a variable speed motor.\u003c\/p\u003e\n\u003ch2\u003eAt a glance\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUp to 1,800 CFM\u003c\/strong\u003e: RS016; RS014 up to 1,400 CFM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e575°F intermittent\u003c\/strong\u003e: 482°F continuous flue gas\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e120V, 1600 RPM\u003c\/strong\u003e: Variable speed, Class H motor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETL listed\u003c\/strong\u003e: UL 378 and CAN3-B255-M81\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eRS014, RS016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUse\u003c\/th\u003e\n\u003ctd\u003eGas and oil fired fireplaces, stoves, BBQs and pizza ovens (non-solid fuel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCapacity\u003c\/th\u003e\n\u003ctd\u003eRS014: 0 to 1,400 CFM. RS016: 0 to 1,800 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical\u003c\/th\u003e\n\u003ctd\u003e1 x 120 VAC, 60 Hz. RS014: 1.4 A. RS016: 3.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSpeed\u003c\/th\u003e\n\u003ctd\u003e1600 RPM, variable speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor output\u003c\/th\u003e\n\u003ctd\u003eRS014: 1\/7 hp. RS016: 1\/3 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor\u003c\/th\u003e\n\u003ctd\u003eTotally enclosed, split capacitor, Class H insulation, IP54, sealed ball bearings, thermal overload protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003eRS014: 47 lbs (21 kg). RS016: 61 lbs (28 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFan width (B x B)\u003c\/th\u003e\n\u003ctd\u003eRS014: 16.6 in. RS016: 18.8 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConstruction\u003c\/th\u003e\n\u003ctd\u003e3\/16 in. cast aluminum housing in grey hammer paint, stainless steel axial vane, horizontal discharge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature rating\u003c\/th\u003e\n\u003ctd\u003e575°F (300°C) intermittent, 482°F (250°C) continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard equipment\u003c\/th\u003e\n\u003ctd\u003eJunction box with cover and conduit, fiber mat and mounting brackets, bird screen, 5 amp fan speed control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eListings\u003c\/th\u003e\n\u003ctd\u003eETL listed to UL 378 and CAN3-B255-M81, for non-solid fuel installations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eEnervex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eA safety interlock with the appliance is required.\u003c\/strong\u003e Enervex's manual calls for a safety system, such as a proven draft switch, that shuts the appliance down on low draft, fan failure or power failure. Installation and wiring must be done by a qualified person to local codes or the National Electrical Code, and we recommend a licensed electrician for the wiring.\u003c\/p\u003e\n\u003ch2\u003eQuestions people ask us\u003c\/h2\u003e\u003ch3\u003eWhich size do I need, RS014 or RS016?\u003c\/h3\u003e\u003cp\u003eThe RS014 moves up to \u003cb\u003e1,400 CFM\u003c\/b\u003e and the RS016 up to \u003cb\u003e1,800 CFM\u003c\/b\u003e. The right size depends on the appliance, the flue size and the chimney height. \u003ca href=\"\/pages\/contact-us\"\u003eSend us\u003c\/a\u003e those details and we will help size it with Enervex before you order.\u003c\/p\u003e\u003ch3\u003eCan I use the RS on a wood burning fireplace?\u003c\/h3\u003e\u003cp\u003eNo. The RS is listed for \u003cb\u003enon-solid fuel\u003c\/b\u003e installations, meaning gas and oil. For wood, pellet or other solid fuel, Enervex makes the \u003ca href=\"\/products\/enervex-rsht-high-temperature-chimney-fan\"\u003eRSHT high temperature chimney fan\u003c\/a\u003e.\u003c\/p\u003e\u003ch3\u003eDoes it come with a speed control?\u003c\/h3\u003e\u003cp\u003eYes. Enervex lists a \u003cb\u003e5 amp fan speed control\u003c\/b\u003e as standard equipment, along with the junction box, fiber mat, mounting brackets and bird screen. For automatic control with a damper and gas valve interlock, look at the \u003ca href=\"\/products\/enervex-adc100-fan-and-damper-control\"\u003eADC100 fan and damper control\u003c\/a\u003e.\u003c\/p\u003e\u003ch3\u003eWill it fit a metal chimney?\u003c\/h3\u003e\u003cp\u003eYes. On a brick chimney the fan sits on the fiber mat. On a round steel chimney it mounts on a \u003ca href=\"\/products\/enervex-sca-steel-chimney-adapter\"\u003eSCA steel chimney adapter\u003c\/a\u003e, and an air cooled steel chimney needs the \u003ca href=\"\/products\/enervex-asca-steel-chimney-adapter\"\u003eASCA adapter\u003c\/a\u003e.\u003c\/p\u003e\u003ch3\u003eHow often does it need cleaning?\u003c\/h3\u003e\u003cp\u003eEnervex says to inspect the fan at least \u003cb\u003eonce a year\u003c\/b\u003e along with the chimney and remove any residue from the blades and the base of the motor housing. Turn the power off before opening the hinged top.\u003c\/p\u003e","brand":"Enervex","offers":[{"title":"RS014","offer_id":67630601634066,"sku":"RS014","price":4225.0,"currency_code":"USD","in_stock":true},{"title":"RS016","offer_id":67630601666834,"sku":"RS016","price":6137.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/2279\/1186\/files\/enervex-rs-chimney-fan.png?v=1792561303"},{"product_id":"enervex-rsht-high-temperature-chimney-fan","title":"Enervex RSHT High Temperature Chimney Fan, 120V","description":"\u003cp\u003e\u003cb\u003eThe Enervex RSHT is a high temperature chimney top exhaust fan with a stainless steel housing, made for solid fuel appliances.\u003c\/b\u003e It mounts on top of the chimney and pulls smoke up and out of the flue, so a wood fireplace, stove, BBQ or pizza oven drafts properly. It comes in four sizes, RSHT009, RSHT012, RSHT014 and RSHT016, all on 120 volts with a variable speed motor.\u003c\/p\u003e\n\u003ch2\u003eAt a glance\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1400°F intermittent\u003c\/strong\u003e: 1000°F continuous flue gas\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e280 to 1,480 CFM\u003c\/strong\u003e: Across the four sizes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e120V variable speed\u003c\/strong\u003e: 5 amp speed control included\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless steel\u003c\/strong\u003e: Housing and axial vane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eRSHT009, RSHT012, RSHT014, RSHT016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUse\u003c\/th\u003e\n\u003ctd\u003eSolid fuel fireplaces, stoves, BBQs and pizza ovens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCapacity\u003c\/th\u003e\n\u003ctd\u003eRSHT009: 0 to 280 CFM. RSHT012: 0 to 575 CFM. RSHT014: 0 to 875 CFM. RSHT016: 0 to 1,480 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e1 x 120 VAC, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmperage\u003c\/th\u003e\n\u003ctd\u003eRSHT009: 0.65 A. RSHT012: 1.33 A. RSHT014: 2.7 A. RSHT016: 4.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003eRSHT009: 25.6 lbs. RSHT012: 33.5 lbs. RSHT014: 41.9 lbs. RSHT016: 47.2 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFan width (B x B)\u003c\/th\u003e\n\u003ctd\u003eRSHT009: 11.7 in. RSHT012: 14.3 in. RSHT014: 16.6 in. RSHT016: 18.8 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConstruction\u003c\/th\u003e\n\u003ctd\u003e3\/16 in. stainless steel housing with black paint, stainless steel axial vane, horizontal discharge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor\u003c\/th\u003e\n\u003ctd\u003eTotally enclosed, split capacitor, variable speed, IP54, sealed ball bearings, thermal overload protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature rating\u003c\/th\u003e\n\u003ctd\u003e1400°F (760°C) intermittent, 1000°F continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard equipment\u003c\/th\u003e\n\u003ctd\u003eJunction box with cover and conduit, fiber mat and mounting brackets, bird screen, 5 amp fan speed control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eListings\u003c\/th\u003e\n\u003ctd\u003eETL listed to UL 378 and CSA CAN3-B255-M81\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eEnervex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eHave it installed and wired by a qualified person.\u003c\/strong\u003e Enervex's manual calls for installation and wiring by a qualified person to local codes or the National Electrical Code, with a disconnect supplied by the installer and the unit grounded. We recommend a licensed electrician for the wiring and a certified chimney sweep for cleaning.\u003c\/p\u003e\n\u003ch2\u003eQuestions people ask us\u003c\/h2\u003e\u003ch3\u003eWhich RSHT size do I need?\u003c\/h3\u003e\u003cp\u003eCapacity runs from \u003cb\u003e280 CFM\u003c\/b\u003e on the RSHT009 to \u003cb\u003e1,480 CFM\u003c\/b\u003e on the RSHT016. Sizing depends on the appliance, the flue size and the chimney height, so \u003ca href=\"\/pages\/contact-us\"\u003esend us\u003c\/a\u003e those details and we will check the size with Enervex before you order.\u003c\/p\u003e\u003ch3\u003eCan I use it with gas?\u003c\/h3\u003e\u003cp\u003eThe RSHT is made for solid fuel. Enervex allows gas or oil use only with a safety system as set out in its separate gas and oil instructions. For gas fireplaces, the \u003ca href=\"\/products\/enervex-rs-chimney-fan\"\u003eRS chimney fan\u003c\/a\u003e is the usual choice.\u003c\/p\u003e\u003ch3\u003eHow does it mount on my chimney?\u003c\/h3\u003e\u003cp\u003eOn a brick chimney the fan sits on the supplied fiber mat. On a round steel chimney it mounts on a \u003ca href=\"\/products\/enervex-sca-steel-chimney-adapter\"\u003eSCA steel chimney adapter\u003c\/a\u003e, and an air cooled steel chimney needs a special adapter. Steel chimneys more than 20 ft above the roof should be braced with wires at 2 to 3 points.\u003c\/p\u003e\u003ch3\u003eCan I run two fans on one chimney?\u003c\/h3\u003e\u003cp\u003eYes, with a special adapter plate of 14 gauge or thicker. The fans must be the same model and size and run together from one speed control.\u003c\/p\u003e\u003ch3\u003eHow often should it be cleaned?\u003c\/h3\u003e\u003cp\u003eInspect the fan at least \u003cb\u003eonce a year\u003c\/b\u003e with the chimney. Enervex suggests chimney cleaning about twice a year for regular fireplace use, more often for daily use, and every 2 to 3 months for commercial pizza ovens.\u003c\/p\u003e","brand":"Enervex","offers":[{"title":"RSHT009","offer_id":67630601830674,"sku":"RSHT009","price":3903.0,"currency_code":"USD","in_stock":true},{"title":"RSHT012","offer_id":67630601863442,"sku":"RSHT-12","price":4608.0,"currency_code":"USD","in_stock":true},{"title":"RSHT014","offer_id":67630601896210,"sku":"RSHT014","price":4954.0,"currency_code":"USD","in_stock":true},{"title":"RSHT016","offer_id":67630601928978,"sku":"RSHT016","price":7194.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/2279\/1186\/files\/enervex-rsht-high-temperature-chimney-fan.png?v=1792561353"},{"product_id":"enervex-sca-steel-chimney-adapter","title":"Enervex SCA Steel Chimney Adapter for RS and RSHT Chimney Fans","description":"\u003cp\u003e\u003cb\u003eThe Enervex SCA is a stainless steel adapter that mounts an Enervex chimney fan on top of a round steel chimney.\u003c\/b\u003e A square plate carries the fan and a 5 inch deep round collar slides into the chimney for a snug fit. Choose the fan size and the chimney size: part numbers FR2008, FR2010, 221.0300.3006, 221.0300.3007, FR3010, FR3012, FR3014, FR3016, FR4012, FR4014 and FR4016.\u003c\/p\u003e\n\u003ch2\u003eAt a glance\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e5 in. deep collar\u003c\/strong\u003e: Slides into the chimney\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e316L stainless\u003c\/strong\u003e: 16 gauge\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e6 to 16 in.\u003c\/strong\u003e: Chimney sizes listed here\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle or double wall\u003c\/strong\u003e: Round steel chimneys\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDetails\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003ePart numbers\u003c\/th\u003e\n\u003ctd\u003eRS 009 size: FR2008 (8 in.), FR2010 (10 in.). RS 012 or RS 014 size: 221.0300.3006 (6 in.), 221.0300.3007 (7 in.), FR3010 (10 in.), FR3012 (12 in.), FR3014 (14 in.), FR3016 (16 in.). RS 016 size: FR4012 (12 in.), FR4014 (14 in.), FR4016 (16 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnervex series\u003c\/th\u003e\n\u003ctd\u003e221.0300 series in Enervex's SCA chart; FR2008 is 221.0300.2008, FR3010 is 221.0300.3010 and so on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUse\u003c\/th\u003e\n\u003ctd\u003eMounting an Enervex RS, RSHT, RSV or GSV fan on a single or double wall round steel chimney\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlue size\u003c\/th\u003e\n\u003ctd\u003eThe inside diameter of the steel chimney\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCollar\u003c\/th\u003e\n\u003ctd\u003e5 in. deep, outside diameter 1\/8 in. smaller than the chimney inside diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003e16 gauge 316L stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation\u003c\/th\u003e\n\u003ctd\u003eSlides into the chimney; can be secured with long self-tapping stainless steel screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eEnervex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eMeasure the inside diameter of the chimney.\u003c\/strong\u003e The collar is made 1\/8 in. under the chimney inside diameter, so order by the actual inside size of the flue, not the outside of the pipe. An air cooled steel chimney needs the ASCA adapter instead.\u003c\/p\u003e\n\u003ch2\u003eQuestions people ask us\u003c\/h2\u003e\u003ch3\u003eHow do I pick the right one?\u003c\/h3\u003e\u003cp\u003ePick the fan size first, then the \u003cb\u003einside diameter\u003c\/b\u003e of your steel chimney. For example, an RS014 on a 10 in. chimney takes FR3010. \u003ca href=\"\/pages\/contact-us\"\u003eSend us your fan and chimney\u003c\/a\u003e if you want us to check it.\u003c\/p\u003e\u003ch3\u003eDoes it work with the RSHT fans?\u003c\/h3\u003e\u003cp\u003eYes. Enervex makes the SCA for its RS and RSHT chimney fans. Its size chart is laid out by RS fan size, so \u003ca href=\"\/pages\/contact-us\"\u003esend us\u003c\/a\u003e your RSHT model and chimney size and we will confirm the part number with you.\u003c\/p\u003e\u003ch3\u003eMy chimney is air cooled. Is this the right adapter?\u003c\/h3\u003e\u003cp\u003eNo. For a double walled, air cooled chimney, Enervex uses the \u003ca href=\"\/products\/enervex-asca-steel-chimney-adapter\"\u003eASCA steel chimney adapter\u003c\/a\u003e, which lets air move between the inner and outer walls.\u003c\/p\u003e\u003ch3\u003eDo I need it on a brick chimney?\u003c\/h3\u003e\u003cp\u003eUsually not. On a masonry chimney the RS and RSHT fans sit on the fiber mat supplied with the fan. The SCA is for round steel chimneys.\u003c\/p\u003e","brand":"Enervex","offers":[{"title":"RS 009 \/ 8 in.","offer_id":67630602289426,"sku":"FR2008","price":500.0,"currency_code":"USD","in_stock":true},{"title":"RS 009 \/ 10 in.","offer_id":67630602322194,"sku":"FR2010","price":476.0,"currency_code":"USD","in_stock":true},{"title":"RS 012 or RS 014 \/ 6 in.","offer_id":67630602354962,"sku":"221.0300.3006","price":500.0,"currency_code":"USD","in_stock":true},{"title":"RS 012 or RS 014 \/ 7 in.","offer_id":67630602387730,"sku":"221.0300.3007","price":500.0,"currency_code":"USD","in_stock":true},{"title":"RS 012 or RS 014 \/ 10 in.","offer_id":67630602420498,"sku":"FR3010","price":476.0,"currency_code":"USD","in_stock":true},{"title":"RS 012 or RS 014 \/ 12 in.","offer_id":67630602453266,"sku":"FR3012","price":605.0,"currency_code":"USD","in_stock":true},{"title":"RS 012 or RS 014 \/ 14 in.","offer_id":67630602486034,"sku":"FR3014","price":605.0,"currency_code":"USD","in_stock":true},{"title":"RS 012 or RS 014 \/ 16 in.","offer_id":67630602518802,"sku":"FR3016","price":605.0,"currency_code":"USD","in_stock":true},{"title":"RS 016 \/ 12 in.","offer_id":67630602551570,"sku":"FR4012","price":605.0,"currency_code":"USD","in_stock":true},{"title":"RS 016 \/ 14 in.","offer_id":67630602584338,"sku":"FR4014","price":605.0,"currency_code":"USD","in_stock":true},{"title":"RS 016 \/ 16 in.","offer_id":67630602617106,"sku":"FR4016","price":605.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/2279\/1186\/files\/enervex-sca-steel-chimney-adapter.png?v=1792561400"},{"product_id":"enervex-301-0108-1200-fsc8-fan-speed-control-8a","title":"Enervex FSC 8 Fan Speed Control, 8 A | 301.0108.1200","description":"\u003cp\u003e\u003cb\u003eThe Enervex FSC 8 is an 8 amp fan speed control for single phase, 120 volt Enervex fans.\u003c\/b\u003e It has a rotary on and off switch with silver alloy contacts. Enervex makes the FSC for its RS, RSHT, RSV and GSV fans, and the 8 amp size covers a higher fan load than the 5 amp control. Part number 301.0108.1200.\u003c\/p\u003e\n\u003ch2\u003eAt a glance\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e8 A max load\u003c\/strong\u003e: Single phase fans\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1 x 120 VAC\u003c\/strong\u003e: 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRotary on and off\u003c\/strong\u003e: Silver alloy contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRS, RSHT, RSV, GSV\u003c\/strong\u003e: Enervex fans\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDetails\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003e301.0108.1200 (FSC 8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum load\u003c\/th\u003e\n\u003ctd\u003e8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e1 x 120 VAC, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitch\u003c\/th\u003e\n\u003ctd\u003eRotary on and off with silver alloy contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUse with\u003c\/th\u003e\n\u003ctd\u003eSingle phase Enervex RS, RSHT, RSV and GSV fans\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNot for\u003c\/th\u003e\n\u003ctd\u003eThree phase RSV and GSV 400 and 450 models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eEnervex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eHave it wired by a qualified person.\u003c\/strong\u003e Enervex's fan manuals call for wiring by a qualified person to local codes or the National Electrical Code. We recommend a licensed electrician.\u003c\/p\u003e\n\u003ch2\u003eQuestions people ask us\u003c\/h2\u003e\u003ch3\u003eDo I need this if my fan came with a speed control?\u003c\/h3\u003e\u003cp\u003eEnervex RS and RSHT fans ship with a \u003cb\u003e5 amp\u003c\/b\u003e speed control. The 8 amp FSC is for a larger load, such as a bigger fan. \u003ca href=\"\/pages\/contact-us\"\u003eSend us\u003c\/a\u003e your fan models and we will confirm which control you need.\u003c\/p\u003e\u003ch3\u003eWill it run a three phase fan?\u003c\/h3\u003e\u003cp\u003eNo. It is for single phase, 120 volt fans. Three phase models need a different control.\u003c\/p\u003e\u003ch3\u003eWhich fans can it control?\u003c\/h3\u003e\u003cp\u003eEnervex makes the FSC for its single phase \u003ca href=\"\/products\/enervex-rs-chimney-fan\"\u003eRS\u003c\/a\u003e, \u003ca href=\"\/products\/enervex-rsht-high-temperature-chimney-fan\"\u003eRSHT\u003c\/a\u003e, RSV and GSV fans.\u003c\/p\u003e","brand":"Enervex","offers":[{"title":"Default Title","offer_id":67631392391442,"sku":"301.0108.1200","price":227.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/2279\/1186\/files\/enervex-301-0108-1200-fsc8-fan-speed-control-8a.jpg?v=1792597687"},{"product_id":"enervex-601-0800-0064-25-mfd-capacitor","title":"Enervex 25 MFD Capacitor | 601.0800.0064","description":"\u003cp\u003e\u003cb\u003eEnervex 601.0800.0064 is a 25 MFD replacement capacitor, as listed by our distributor.\u003c\/b\u003e No fan model is named in the listing, so send us the model and serial number from your Enervex fan, and a photo of the old capacitor, and we will check fit before you buy.\u003c\/p\u003e\n\u003ch2\u003eAt a glance\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e25 MFD\u003c\/strong\u003e: Rating as listed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan capacitor\u003c\/strong\u003e: Enervex part\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e601.0800.0064\u003c\/strong\u003e: Enervex part number\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFit check\u003c\/strong\u003e: Send model and serial first\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDetails\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003e601.0800.0064\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDescription as listed\u003c\/th\u003e\n\u003ctd\u003e25 mfd capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRating\u003c\/th\u003e\n\u003ctd\u003e25 MFD, as listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eListed fit\u003c\/th\u003e\n\u003ctd\u003eNo fan model named by the distributor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePart type\u003c\/th\u003e\n\u003ctd\u003eCapacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAvailability\u003c\/th\u003e\n\u003ctd\u003eAsk us for current stock and lead time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eEnervex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSwitch off power at the breaker first.\u003c\/strong\u003e A capacitor can hold a charge after power is off. Disconnect power before opening the fan's junction box, follow the Enervex installation manual, and have a licensed electrician do the work where local codes call for one.\u003c\/p\u003e\n\u003ch2\u003eQuestions people ask us\u003c\/h2\u003e\u003ch3\u003eWill this fit my chimney fan?\u003c\/h3\u003e\u003cp\u003eConfirm your model and serial number before ordering; send them to us and we will check fit before you buy. Both are on the fan's label, and a photo of the old capacitor's label helps too. \u003ca href=\"\/pages\/contact-us\"\u003eSend them here\u003c\/a\u003e.\u003c\/p\u003e\u003ch3\u003eWhat is included?\u003c\/h3\u003e\u003cp\u003eAs listed by our distributor: \u003cb\u003eone capacitor\u003c\/b\u003e, part 601.0800.0064. Wiring and hardware are not part of this listing.\u003c\/p\u003e\u003ch3\u003eQuestions about returns or lead time?\u003c\/h3\u003e\u003cp\u003eReach us through our \u003ca href=\"\/pages\/contact-us\"\u003econtact page\u003c\/a\u003e before you order. We will go over fit, current stock, lead time and our return terms for parts like this one.\u003c\/p\u003e","brand":"Enervex","offers":[{"title":"Default Title","offer_id":67636504461586,"sku":"601.0800.0064","price":95.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/2279\/1186\/files\/enervex-601-0800-0064-25-mfd-capacitor.png?v=1792699618"},{"product_id":"enervex-604-0400-0064-capacitor-for-rs014-12-mfd","title":"Enervex Capacitor for RS014 Chimney Fan, 12 MFD | 604.0400.0064","description":"\u003cp\u003e\u003cb\u003eEnervex 604.0400.0064 is a 12 MFD replacement capacitor, listed by our distributor for the Enervex RS014 chimney fan.\u003c\/b\u003e The Enervex RS installation manual shows the capacitor as a part inside the fan's junction box. Send us the model and serial number from your fan and we will check fit before you buy.\u003c\/p\u003e\n\u003ch2\u003eAt a glance\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRS014\u003c\/strong\u003e: Fit as listed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e12 MFD\u003c\/strong\u003e: Rating as listed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e604.0400.0064\u003c\/strong\u003e: Enervex part number\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFit check\u003c\/strong\u003e: Send model and serial first\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDetails\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003e604.0400.0064\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDescription as listed\u003c\/th\u003e\n\u003ctd\u003eCapacitor for RS014 12 MFD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRating\u003c\/th\u003e\n\u003ctd\u003e12 MFD, as listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eListed fit\u003c\/th\u003e\n\u003ctd\u003eEnervex RS014 chimney fan (fit as listed by the distributor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocation\u003c\/th\u003e\n\u003ctd\u003eInside the fan's junction box, per the RS installation manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAvailability\u003c\/th\u003e\n\u003ctd\u003eAsk us for current stock and lead time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eEnervex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSwitch off power at the breaker first.\u003c\/strong\u003e A capacitor can hold a charge after power is off. Disconnect power before opening the fan's junction box, follow the Enervex installation manual, and have a licensed electrician do the work where local codes call for one.\u003c\/p\u003e\n\u003ch2\u003eQuestions people ask us\u003c\/h2\u003e\u003ch3\u003eWill this fit my chimney fan?\u003c\/h3\u003e\u003cp\u003eConfirm your model and serial number before ordering; send them to us and we will check fit before you buy. Both are on the fan's label, and a photo of the old capacitor's label helps too. \u003ca href=\"\/pages\/contact-us\"\u003eSend them here\u003c\/a\u003e.\u003c\/p\u003e\u003ch3\u003eWhat is included?\u003c\/h3\u003e\u003cp\u003eAs listed by our distributor: \u003cb\u003eone capacitor\u003c\/b\u003e, part 604.0400.0064. Wiring and hardware are not part of this listing.\u003c\/p\u003e\u003ch3\u003eQuestions about returns or lead time?\u003c\/h3\u003e\u003cp\u003eReach us through our \u003ca href=\"\/pages\/contact-us\"\u003econtact page\u003c\/a\u003e before you order. We will go over fit, current stock, lead time and our return terms for parts like this one.\u003c\/p\u003e","brand":"Enervex","offers":[{"title":"Default Title","offer_id":67636504494354,"sku":"604.0400.0064","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/2279\/1186\/files\/enervex-604-0400-0064-capacitor-for-rs014-12-mfd.png?v=1792699619"},{"product_id":"enervex-601-0400-0064-capacitor-for-rs012","title":"Enervex Capacitor for RS012 Chimney Fan | 601.0400.0064","description":"\u003cp\u003e\u003cb\u003eEnervex 601.0400.0064 is a replacement capacitor, listed by our distributor for the Enervex RS012 chimney fan.\u003c\/b\u003e The Enervex RS installation manual shows the capacitor as a part inside the fan's junction box. Send us the model and serial number from your fan and we will check fit before you buy.\u003c\/p\u003e\n\u003ch2\u003eAt a glance\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRS012\u003c\/strong\u003e: Fit as listed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacitor\u003c\/strong\u003e: Fan part\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e601.0400.0064\u003c\/strong\u003e: Enervex part number\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFit check\u003c\/strong\u003e: Send model and serial first\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDetails\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003e601.0400.0064\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDescription as listed\u003c\/th\u003e\n\u003ctd\u003eCapacitor for RS012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eListed fit\u003c\/th\u003e\n\u003ctd\u003eEnervex RS012 chimney fan (fit as listed by the distributor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocation\u003c\/th\u003e\n\u003ctd\u003eInside the fan's junction box, per the RS installation manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAvailability\u003c\/th\u003e\n\u003ctd\u003eAsk us for current stock and lead time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eEnervex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSwitch off power at the breaker first.\u003c\/strong\u003e A capacitor can hold a charge after power is off. Disconnect power before opening the fan's junction box, follow the Enervex installation manual, and have a licensed electrician do the work where local codes call for one.\u003c\/p\u003e\n\u003ch2\u003eQuestions people ask us\u003c\/h2\u003e\u003ch3\u003eWill this fit my chimney fan?\u003c\/h3\u003e\u003cp\u003eConfirm your model and serial number before ordering; send them to us and we will check fit before you buy. Both are on the fan's label, and a photo of the old capacitor's label helps too. \u003ca href=\"\/pages\/contact-us\"\u003eSend them here\u003c\/a\u003e.\u003c\/p\u003e\u003ch3\u003eWhat is included?\u003c\/h3\u003e\u003cp\u003eAs listed by our distributor: \u003cb\u003eone capacitor\u003c\/b\u003e, part 601.0400.0064. Wiring and hardware are not part of this listing.\u003c\/p\u003e\u003ch3\u003eQuestions about returns or lead time?\u003c\/h3\u003e\u003cp\u003eReach us through our \u003ca href=\"\/pages\/contact-us\"\u003econtact page\u003c\/a\u003e before you order. We will go over fit, current stock, lead time and our return terms for parts like this one.\u003c\/p\u003e","brand":"Enervex","offers":[{"title":"Default Title","offer_id":67636635140370,"sku":"601.0400.0064","price":48.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/2279\/1186\/files\/enervex-601-0400-0064-capacitor-for-rs012.png?v=1792702434"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/2279\/1186\/collections\/Enervex_Logo.jpg?v=1793323625","url":"https:\/\/www.aquaterrabackyard.com\/collections\/enervex\/chimney-venting-systems.oembed","provider":"Aqua Terra Backyard","version":"1.0","type":"link"}